Nuclear magnetic resonance (NMR) is a nucleus with magnetic moment not zero. In the field of external magnetic field, the spin energy level is divided into a secant, and resonance absorbs the physical process of a certain frequency of radiofrequency radiation.Nuclear magnetic resonance spectroscopy is a branch of spectroscopy. Its resonance frequency is in the radio frequency band, and the corresponding transition is the nuclear spin transition on the nuclear seaman energy level.
Application Case
Application

NdFeB magnet has a wide range of applications in the medical field, and Roco Magnetics has accumulated rich experience in this field. We know how to help our customers save time and money.For the new projects, we are happy to provide your company with the most suitable and cost-effective magnet customization solutions.

1
2
3
4
Technical Requirement

1、Servicelife 220 years

2、Grade: 35UH, 38UH, 35EH, 38EH

3、 Density: 27.6g/cm'

4、Magnetic Flux Consistency. Testing fux in the same testing equipment in the room temperature. The maximum deviation     value of flux is less than3%

5、Thermal demagnetization:

Test conditions; baking 2 hoursin 180C

Eligibility criteria: The average value of the fluw ireversible loss is less than 1% in the same motor, and the fux   freversible loss of single magnet is less than 2%

6、Weight Loss.

HAST Testing(unsaturated humidity, without coating)

 Test conditions: Temp:120C. Pressure: 0.27MPa Humidity: 80% Testing time. 240hours.

Eligibility criteria: the average value of weight loss is less than 2mg/cm? in the same motor, and weight loss of single    magnet is less than 3mg/cmf

7、Coating:

High Temperature Resistant Testing:

Test conditions : baking 2 hoursin 250C

Eligibilty criteria: no blistering and no discoloring

Cold and Hot Shock Testing

Test conditions : keeping 150C for 30mins, and then keeping -50^C for 30mins which is one cycleTesting 240 cycles.Eligibility criteria: no peeling, 

no blistering and no rust

Test conditions:

Temp :85*C. Humidity : 85%. Testing time: 240hoursEligibility criteria: no peeling,

no blistering and no rust

PCT Testing(saturated humidity, with coating)

Test conditions: Temp:120*C. Pressure: 0.27MPa. Humidity: 100%. Testing time: 168hoursEigibility criteria: no peeling,

no blistering and no rust

Salt Spray Test

Test conditions: Temp.:35"C. NaC:.5%. PH:6.5-7.2, Testing time: 2300hoursEligibility criteria: no peeling,

no blistering and no rust

 